News

Technical Requirements Of Electrodeionization System

Jan 13, 2025 Leave a message

 

Electrodeionization (EDI) system is a key technology in the field of modern water treatment, and its technical requirements are strict and critical.

First, EDI inlet water needs to have corresponding indicators. Qualified inlet water is crucial. Unqualified inlet water can easily damage the EDI membrane stack. The life of the membrane stack, the quality of the produced water and the frequency of maintenance depend on the quality of the inlet water. Usually RO permeate water is suitable as inlet water. The inlet water needs to control parameters such as flow, pressure and conductivity to ensure the long-term stable operation of the system. For example, RO permeate can be deeply desalinated by the electrodeionization system. The inlet water flow, pressure and low conductivity need to be stabilized to ensure that the inlet water quality meets the standard.

Secondly, the EDI system has requirements for working pressure. Due to the limited strength of its membrane stack and internal sealing conditions, the operating pressure cannot be too high. The maximum working pressure is 0.4MPa, and the pressure of the fresh water chamber is generally 0.03-0.07MPa higher than that of the concentrated water chamber to prevent concentrated water from infiltrating into the product water.

Furthermore, current, voltage and resistance are also clearly specified. The current of the EDI membrane stack is the result of ion migration and water electrolysis. The maximum operating current cannot be higher than 5A. The current during actual operation should be determined according to the on-site conditions. When multiple membrane stacks use a DC power supply, the voltage and current of each membrane stack should be independently adjustable and equipped with corresponding monitoring instruments.

EDI water treatment system 3

In addition, the recovery rate is also an important indicator. The water recovery rate of the EDI membrane stack is defined as the ratio of the recovered product water flow rate to the inlet water flow rate. Its reasonable control is related to the system processing efficiency and water quality.

Finally, the design of the EDI system needs to focus on stable operation, including optimization of the pre-treatment system and other considerations. It is also necessary to pay attention to the system's operating specifications and safety, regularly test water quality, record operating parameters, etc., to ensure the long-term stable operation of the system and provide high-quality water treatment services for various industries.