This commercial reverse osmosis system purifies high-volume municipal or well feed water into low-TDS potable water for commercial and institutional facilities. Engineered for continuous operation, the skid-mounted unit integrates automated multi-stage pre-treatment, high-pressure membrane separation, and precision instrumentation to deliver consistent, high-purity water.
Technical Specifications
|
Core Parameter |
Specification Range |
|
Permeate Flow Rate |
1,000 GPD to 10,000 GPD (3.8 m3/day to 37.8 m3/day) |
|
Salt Rejection Rate |
99.2% nominal stabilization |
|
System Recovery |
50% to 75% adjustable |
|
Operating Pressure |
150 PSI to 225 PSI (10.3 bar to 15.5 bar) |
|
Electrical Supply |
220V / 380V, 50Hz / 60Hz, 3-phase |
Purification Workflow
Sediment Filtration: 5-micron depth filters capture suspended solids and particulate matter to protect downstream components.
Carbon Adsorption: Granular activated carbon removes free chlorine and organic compounds that degrade polyamide membranes.
Pressure Boosting: Vertical multi-stage centrifugal pumps increase line pressure to overcome natural osmotic resistance.
Membrane Separation: Spiral-wound semi-permeable elements block dissolved ions, heavy metals, and microorganisms.
Hardware Configuration
Booster Pump: Stainless steel centrifugal pump equipped with integrated dry-run protection.
Pressure Vessels: Seamless 304 or 316 stainless steel housings rated for 300 PSI limits.
Control Unit: Programmable Logic Controller (PLC) with an LCD interface for real-time system monitoring.
Hydraulic Piping: PVC-U schedule 80 low-pressure lines and 304 stainless steel high-pressure discharge piping.
Feed Water Requirements
Maximum TDS: Up to 2,000 ppm for standard builds; higher levels require customized pre-treatment engineering.
Free Chlorine: Below 0.1 ppm to prevent oxidation damage to polyamide membrane layers.
Silt Density Index: SDI under 5.0 verified through standard 15-minute testing protocols.
Temperature Window: Operational feed water temperature maintained between 5°C and 35°C.
Permeate Water Quality
Mineral Reduction: Achieves 95% to 98% reduction in total dissolved solids.
Microbial Barrier: Complete physical removal of bacteria, cysts, and viruses via 0.0001-micron pores.
Organics Removal: Eliminates synthetic organic compounds, herbicides, and volatile residuals.
Organoleptic Profile: Produces neutral-tasting, odorless water suitable for direct consumption.
Post-Treatment Options
UV Sterilization: Inline 254nm ultraviolet disinfection chamber inactivates residual microorganisms.
Remineralization: Calcite and corosex media reintroduces controlled calcium and magnesium to balance pH.
Polishing Filtration: Granular activated carbon stage removes trace tastes for strict institutional standards.
Degassification: Membrane degassing units or caustic dosing to stabilize low-pH permeate streams.
Target Applications
Commercial Offices: Centralized hydration stations, pantry supply lines, and beverage vending setups.
Hospitality: Hotel room supply networks, commercial kitchen food preparation, and ice maker feeds.
Healthcare: Patient ward drinking stations, clinic utility rooms, and laboratory equipment supply loops.
Educational Facilities: Campus dormitory water stations, cafeteria distribution points, and sports hydration hubs.
System Sizing Guide
Flow Calculation: Determine peak hourly and daily consumption volumes to select nominal gallon capacity.
Water Analysis: Review certified water test reports detailing hardness, iron, silica, and TDS levels.
Space Planning: Verify mechanical room footprint, ceiling clearance, and doorway access for skid dimensions.
Utility Check: Confirm local floor drain proximity and industrial electrical panel amperage availability.
Customization Options
Frame Material: Powder-coated carbon steel or full 304/316 stainless steel sanitary skids.
Instrumentation: Integration of inline pH sensors, ORP meters, and digital flow totalizers with Modbus protocols.
Dual-Pass Design: Secondary RO stage incorporation for ultra-low conductivity requirements below 10 microsiemens.
Cabinet Enclosures: Weatherproof fiberglass or steel enclosures fitted with climate control for outdoor installations.
Quality Control Protocols
Hydrostatic Testing: Pressure vessels and high-pressure piping tested at 1.5 times working pressure for 30 minutes.
Electrical Inspection: Insulation resistance and ground continuity verified against international electrical codes.
Factory Wet Testing: Complete operational dry-run and water-flow testing performed prior to skid crating.
Material Traceability: Material test reports (MTR) provided for stainless steel components and pressure vessels.